Generator Mounting - Location
The complete generator unit is mounted on lightweight rails by means
of
four flexible isolator mounts that
help prevent the transfer
of
vibration from the generator to the rails. Each generator mounting rail has
several
112
inch bolt holes
so
bolts can be employed to properly secure the generator to its mounting
platform.
The mounting location
must be dry, above low-lying vapor areas, and
in
an area where bilge water and
water from above cannot splash or drip on the generator or drive engine. The drive engine and generator
must be accessible for minor servicing and repairs. Access for major repairs should be given
consideration as well. The generator set
must be properly ventilated to provide fresh cooling air for the
generator end, for engine combustion needs, and to remove heat produced by the engine while operating.
The generator set needs fresh cool air in whatever location in the vessel it
is
installed. Hot generator
discharge air
!!lli§!. be removed from the generator area. The platform on which the generator and its
mounting rails are located
must be strong enough to support the generator during all angles
of
vessel
operation.