Component Removal and Replacement
R500 - Laser
Table of Contents
Handle the laser with care! Do not bump or jar it.
1. Make sure the PLS is powered OFF and unplugged.
2. Press the two hinges to release the
latch on the backside of the PLS.
Gently fold back the rear cover.
3. Unplug the electrical connector from
the Laser by manually undoing the
two thumb screws and gently pulling
to the left.
4. Rotate the laser, a few degrees, from
the bottom and lift it up and off the
mounts. Store the Laser in a safe
place.
5. When reinstalling the Laser Tube
slowly rotate the laser cartridge
making sure that the alignment plate
is centered in the gap of the alignment
fork between the small and large
plates.
Note: The PLS6.60 and 6.120D have two laser tubes. The power connectors are
labeled “Top” and “Bottom”. It is very important that you plug in the correct connector
into the appropriate laser; otherwise the laser system will not function properly.